Hitachi Vantara HQT-4180 Practice Exam Questions & Answers
7 Free Questions
· Last reviewed: October 11, 2026
· Prepared & Reviewed by the ValidExamDumps Editorial Team
Exam Facts
Hitachi Vantara HQT-4180 Exam Details
Key details for this exam, checked against the published exam outline
35
Practice Questions (Our Bank)
60 minutes
Exam Duration
65%
Passing Score
- Exam Code
- HQT-4180
- Full Name
- Hitachi Vantara Qualified Professional - VSP Midrange Family Installation
- Issuing Body
- Hitachi Vantara
- Question Format (Our Bank)
- Multiple Choice
- Official Exam Fee
- USD 100 (plus local tax, depending on location)
- Delivery
- Kryterion Webassessor - online proctored or at Kryterion testing centers (onsite proctored)
- Validity
- 3 years
Practice Questions
Free HQT-4180 Practice Questions
Each question shows the correct answer and an explanation of why it is right
VA
ValidExamDumps Editorial Team
Every question and its answer is checked by our HQT-4180 exam
preparation team, who also write the explanation shown with each one.
How we research and review these pages
Which two statements are correct when adding cache to a VSP E590? (Choose two.)
Correct Answer:
A, C
Explanation
The Initial Setup Wizard (ISW) is a configuration tool used during the installation and setup phase of VSP midrange systems. Its primary purpose is to configure the management port IP addresses, which are essential for accessing the storage management interface. The ISW does not configure host-side channel port addresses, backend storage network addresses, or other specialized network settings. Those are handled through different configuration methods and tools after the initial setup phase is complete.
A customer wants to upgrade their VSP E790 with a SAS Expansion feature.
What are three requirements? (Choose three.)
Correct Answer:
A, C, E
Explanation
The VSP G700 supports RAM upgrades using Cache Flush Modules (CFM). To reach 512 GB total RAM capacity, the valid configuration requires two BM45 modules per controller. This specification is based on the G700's architecture and the capacity of individual memory modules. One BM45 per controller would not provide sufficient capacity, while three or more would exceed the supported configuration for this model.
You need to upgrade the firmware on a VSP G700.
Which file must you select to perform the upgrade using the Maintenance Utility?
Correct Answer:
C
Explanation
To separate I/O traffic between servers sharing the same front-end ports, two mechanisms work together. Host Groups allow logical separation so each server's commands are isolated from the other. Port security adds an additional layer by restricting which Host Groups can access specific ports. Without Host Groups alone, there is no logical isolation. Without port security alone, a server could theoretically communicate through both Host Groups. Together, these two controls ensure complete separation of server I/Os.
Which two VSP systems support attached Drive Box Flash (DBF)? (Choose two.)
Correct Answer:
A, C
Explanation
Changing a RAID level during normal operations on VSP systems requires specific procedures. After unmapping the LUNs from the channel ports, the next step is to access the SVP Maintenance window, which is the dedicated interface for performing RAID configuration changes. Making changes directly through other management tools or without using the Maintenance window can compromise data integrity and system stability. The Maintenance window ensures proper coordination of the RAID transformation process.
What are two functions of the LAN Blade in the VSP Midrange family? (Choose two.)
Correct Answer:
A, D
Explanation
Adding a SAS Expansion feature to a VSP E790 requires hardware and software prerequisites. Two additional Disk Boards provide the controller capacity needed. The SAS Expansion license enables the feature at the software level. Drive Boxes with SAS interfaces are required to attach the expanded storage. You cannot use FC or other interface types. Without all three elements, the expansion cannot function. Missing any one of these components makes the upgrade incomplete.
A customer wants to change a production RAID group from RAID 5 (7D+1P) to RAID 6 (6D+2P) on a VSP G600 during normal operations. They have just unmapped the LUNs from the channel ports.
What needs to be performed next?
Correct Answer:
A
Explanation
The LAN Blade is a hardware component in VSP midrange systems that serves two specific functions. It provides the LAN connection to the file module, allowing file-level services to communicate with the network. It also provides the management port that connects the entire storage system to the customer's management LAN. These functions are distinct and essential for overall system connectivity. The LAN Blade does not handle backend storage communication or direct host channel connections.
Question 7
Which program is used to perform the ''New Installation'' procedure on a VSP midrange system?
Correct Answer:
C
Full Access
Get the complete HQT-4180 question set
- 35 questions covering all exam domains
- Correct answers with explanations, like the free questions above
- PDF and online practice test
- 90 days of free updates
Domain 1: Section 1 System architecture
Learn to describe the different VSP midrange storage systems models and their specifications. Study the system architecture, internal components, and their functions in detail.
Sample questions from this domain above:
Q2Q6
Domain 2: Section 2 Back-end Architecture
Understand the back-end architecture and hardware components of VSP midrange storage systems. Focus on drive sparing technology and the concepts behind data protection strategies.
Sample question from this domain above:
Q3
Domain 3: Section 3 System Installation
Master the new installation procedure for VSP midrange storage systems and when to apply it. Learn installation, initial configuration procedures, and how to enable program products on these systems.
Sample questions from this domain above:
Q1Q4Q5
FAQ
HQT-4180 Exam FAQ
Common questions about the exam itself
Is HQT-4180 only for Hitachi Vantara employees or can partners take it too?
Both Hitachi Vantara employees and partners who install VSP midrange storage systems can take HQT-4180. The exam is designed specifically for installation professionals working with Hitachi Virtual Storage Platform midrange storage systems at customer sites.
What background do I need before taking HQT-4180?
The exam is designed for installation professionals who already have strong knowledge of VSP midrange storage system hardware. Recommended supporting courses include 1024PI Installing Hitachi VSP One Block Mid-sized Enterprise or 1290PI Transitioning to Hitachi VSP One Block Mid-sized Enterprise.
How many questions are on HQT-4180 and how much time do I have?
The exam has 35 multiple choice questions and you have 60 minutes to complete it. This is a closed-book proctored examination.
What score do I need to pass HQT-4180?
You need to score 65 percent or higher to pass HQT-4180. This passing score reflects the medium-stakes nature of qualification tests in the Hitachi Vantara Certified Professional program.
How long is the HQT-4180 certification valid for?
Your HQT-4180 credential is valid for 3 years from the date you pass the exam. After 3 years you would need to retake the exam to maintain the credential.
Where can I take HQT-4180 and how is it delivered?
You can take HQT-4180 through Kryterion Webassessor either as an online proctored exam or at a Kryterion testing center for onsite proctoring. Some locations also offer the exam at the conclusion of instructor-led training courses.
What does HQT-4180 cover that other VSP installation exams do not?
HQT-4180 specifically covers midrange VSP systems, whereas HQT-4160 covers VSP 5000 Series Installation for higher-end systems. If you work with VSP midrange storage families you would take HQT-4180 rather than the 5000 Series exam.
What job role is HQT-4180 designed for?
HQT-4180 validates the knowledge and skills of VSP midrange storage installation professionals and engineers. The credential demonstrates competency in installing, configuring, and supporting Hitachi midrange storage systems at customer sites.
Does HQT-4180 cover storage management and support activities?
Yes. The exam covers not just installation and configuration but also basic storage management activities and the tools, techniques, and best practices for supporting and servicing the Hitachi VSP midrange family of systems.
How much does it cost to take HQT-4180?
The exam costs USD 100 or equivalent in local currency, plus local tax depending on your location. This is the standard cost for HQT qualification tests in the Hitachi Vantara Certified Professional program.